Improve this question. BlueSun 3, 1 1 gold badge 17 17 silver badges 34 34 bronze badges. Abdulsalam Elsharif Abdulsalam Elsharif 4, 6 6 gold badges 28 28 silver badges 56 56 bronze badges. I would suggest you use the heat tool instead of this Copy method. Have you managed to solved your problem?
Add a comment. Active Oldest Votes. This solution works with WIX 3. Improve this answer. David Bond 7 7 bronze badges. The solution is to change when the heat command runs as described here: stackoverflow. Works like a charm. Spent a lot of hours trying to understand how it works, read a lot of tutorials and articles but your description is the best so far!
It works, but I don't understand why there are 3 dots in the HarvestPath constant, or why it could not be reused in the HeatDirectory. Directory property. Show 2 more comments. I think you've gotten into a bit of a muddle, if you don't mind me saying so. You can use that in one of two ways: As a development aid Run the tool with this kind of command: heat dir ".
In the build pipeline You can use the Heat tool in the build pipeline, so that compiling the install will generate the code. How to include wxi file into wxs? Ask Question. Asked 12 years, 4 months ago. Active 7 years, 5 months ago. Viewed 25k times. Improve this question. Community Bot 1 1 1 silver badge. Juozas Kontvainis Juozas Kontvainis 8, 6 6 gold badges 51 51 silver badges 65 65 bronze badges.
Add a comment. Active Oldest Votes. The code comments should provide plenty info about what each part does in general. Basically there are 5 major parts. The update part, the conditions and actions part, the UI install sequence, the directory structure and the features we want to include. For more info on what certain attributes mean you should look into the WiX Documentation.
Home SQLTeam. A neat way of overcoming the con of the second option is to have a post-build event on your main application project SuperForm. MainApp in our case to copy the files needed to be installed in a special location and have the Heat. The command line text that you have to put into the pre-build event of your WiX project looks like this:. Remember: for 32 bit applications Program files folder is named differently between 32 and 64 bit systems.
You can view all Heat. If you have source control you have to include the FilesFragment. The auto generated FilesFragment. SuperFormFilesDir will be replaced at build time with the directory where the files to be installed are located.